Speaker cables contribute to load impedance; choose cables whose resistance is appropriate for the load and cable length. Vocia End-of-Line sensing devices monitor out-of-band high frequency tones (21 - 23kHz) to detect speaker line integrity. If using these devices with long speaker cables, choose low capacitance cables so that ELD-1 tones are not excessively attenuated. See the ELD-1 Output Fault Detection section for requirements when using ELD-1s.
The following table must be used when deciding which End of Speaker Line input is required.
| 
 | Amplifier Power | |
| Speaker Circuit | Less than 100 Watts | 100 Watts or greater | 
| 4Ω | Low | Low | 
| 6Ω | Low | Low | 
| 8Ω | Low | Low | 
| 25 Volt | Low | Low | 
| 70 Volt | Low | Low | 
| 100 Volt | Low | High | 
 
                                    