TTS-1e General Settings

Configuration of TTS-1e Sequences is performed in the World Properties window under TTS-1e Sequences.

General

Control Network Settings (LAN-1), has an IP address field that reports the current IP address for the selected TTS-1e that is used for IP communications with the device. The TTS-1e IP Configuration window can be used to set this value or it can be added in this field.

Nurse Call Communications Options

The TTS-1e RS-232 port is able to be used to communicate directly with a Rauland Nurse call system.

Enable Nurse Call - When selected the nurse call functions will be available. This requires additional licensing permissions in order to function. A Nurse Call Service Licence Alarm will indicate if licensing is not enabled.

Default Voice - can be specified. This must be available on the TTS-1e as a licensed voice.

Nurse Call Serial Port Options Settings:

Details of supported Flow Control, RTS and CTS settings:

Rauland

TTS-1e

Flow Control

RTS Use

CTS Use

Flow Control

RTS Enable

DTR Enable

RTSCTS

Any

Any

RTS

Not Available

True/False

 

 

Xon Xoff

Any

Ignore

Xon/Xoff

True/False

True/False

Flow Control

True

True/False

Device Ready

True

True/False

 

 

Flow Off

Any

Ignore

None

True/False

True/False

Flow Control

True

True/False

Device Ready

True

True/False

 

 

DSR_DTR

Any

Ignore

None

True/False

True

Flow Control

True

True

Device Ready

True

True

 

 

DSR_DTR RTS

Any

Any

RTS

Not Available

True

None

True

True

RTS Xon/Xoff

Not Available

True

 

 

DSR_DTR_XON

Any

Ignore

Xon Xoff

True/False

True

Flow Control

True

True

Device Ready

True

True

 

Nurse Call Protocol - Rauland Responder 5 is supported.

Enable Passive Mode - Removes the monitoring of the RS-232 port if required. Please see the TTS-1nce RS-232 Wiring Topologies section for more details.

Enable Serial Communications Monitoring - This monitoring mechanism periodically checks the serial link between the Nurse Call System and the TTS-1. An alarm will be raised if the serial link is detected to be broken.

RS-232 Wiring
Please refer to the TTS-1nce RS-232 Wiring Topologies section for more details on the RS-232 interface connection to the TTS-1nce. Note that the RS-232 port is disabled for the standard TTS-1e (non-Nurse Call).

Rauland Nurse Call Protocol options

Legacy Dial Back Pagers Disabled -

When Legacy Dial Back Pagers is disabled the TAP output format is: Area Description: Room Description: BedIndex

Example: If Area Description = CUBIC, Room Name = P1501, Bed Index = 1, and Call Priority = Patient

The TAP message would appear as: CUBICP1501:1 Patient

Area Field Width is user configurable depending on the settings in the Nurse Call system the TTS-1nce is interfacing to. For non-legacy systems a range between 1 and 5 is supported. These settings must match for correct operation.

Legacy Dial Back Pagers Enabled -

When Legacy Dial Back Pagers is enabled the TAP output format is: Area Dial Number*Room Dial Number*Bed Index

Example 1: If Area Dial Number = 15, Room Dial Number = 1501, Bed Index = 1 (with bed index 1 and 2 being the Patient Beds in the room) and Call Priority = Patient

The TAP message would appear as: 15*1501*1 Patient

Area Field Width is user configurable depending on the settings in the Nurse Call system the TTS-1nce is interfacing to. For legacy systems the field is separated by a *. The length can be variable and longer than 5 characters. These settings must match for correct operation.

When disabled, TTS-1 will not monitor the Serial Communications link. If the Passive Mode is enabled, the Serial Communications Monitoring will automatically disable.